Absen Pakistan logo
SMD Screen Rigging: Hanging vs Ground Stacking for Events (Absen Pakistan guide)

SMD Screen Rigging: Hanging vs Ground Stacking for Events

Quick answer: Hang an SMD screen when the stage or venue has a truss or overhead support that is rated for the load. Ground stack it when there is no overhead point, when the crowd needs a lower screen, or when the show is short and the setup time is tight. Both methods need a qualified rigger for every flown screen. The Absen FL Series supports hanging with adjustable suspension blocks and stacking with front-mounted connectors, so it covers both methods.

What is the difference between hanging and ground stacking?

Hanging means the screen is attached to a truss, a frame or a rigging point above the stage. The screen is lifted into place and stays in the air for the whole event. Ground stacking means the panels are built up from the floor, one row on top of the other, and the finished structure stands on its own base.

Hanging gives a clean look and frees the floor for the crowd and the stage. It also brings the weight overhead, so the rigging points and the truss must be checked before anyone lifts a panel. Ground stacking is slower to view from the back rows at some angles, but it needs less rigging equipment and no overhead point.

Which method suits which event?

The table below sets out the common event types in Pakistan and the method that usually fits.

Event typeUsual methodWhy
Stage concert with a trussHangingScreen sits above the artists and stays clear of the crowd
Open-air stage with no roofGround stackingNo fixed overhead point, and the structure can be built on the stage
Wedding stage or marqueeGround stacking or a small hung frameDepends on the marquee roof and whether the venue allows fixings
Jalsa or rally stageGround stackingQuick build, base set on the stage, and the crowd stays at a safe distance
Curved or cylindrical stage wallHanging with curved blocksThe FL Series makes curved shapes with suspension blocks

How do you check the weight and the truss?

Start with the datasheet for the panel. The weight of one panel, the number of panels in the screen and the load rating of each suspension point decide the rigging. Do not work from a guess or from another brand’s figure. Get the numbers from the Absen datasheet and send them to the rigger.

Check the truss before the screen goes up. Look for the rated load on the truss, the bolts, the clamps and the chain hoists. Make sure the load is spread across several points, not one clamp. Keep the rigging points clear of the power cables and the lighting.

The FL Series supports hanging up to 10 metres high and stacking up to 5 metres high. These heights come from the product specification, but the final safe height depends on the site, the load and the rigger’s assessment on the day.

What changes outdoors?

Wind is the main risk for an outdoor screen. A large flat screen catches the wind like a sail. Before the event, ask for the wind forecast for the day and the wind speed the rigger has planned for. Use bracing, extra ties and a secure base for every ground stack. If the wind rises during the event, lower the screen or stop the show.

Keep the crowd out of the fall zone. Mark a safe area around the stack or under the hung screen, and check it again before the doors open. Power cables and the generator must be placed where the wind and the crowd cannot reach them.

What should you check before the crowd arrives?

  • Rigging points: confirm each point is rated for the load and is inspected on the day.
  • Truss and bolts: check that every bolt and clamp is tight and undamaged.
  • Panel locks: check that the front and rear locks are closed on every panel.
  • Cables: run the data and power cables away from the crowd and the rigging line.
  • Wind plan: agree on the wind speed at which the show stops.
  • Safe zone: mark the fall zone and keep the crowd behind it.
  • Qualified rigger: a qualified rigger signs off the flown screen before the audience enters.

Common mistakes

A common mistake is to hang a screen from a point that was never built for it, such as a tent pole or a light stand. Another is to use a truss without checking its rating. Teams also tend to forget the wind until the screen is already up. Plan the rigging with the stage designer, the sound team and the venue manager at the same time.

Irfan Corporation, the authorised Absen distributor in Pakistan, can check the panels, the connectors and the suspension blocks before the event, and can give a written quotation for the setup you need. For the rigging itself, use a qualified rigger.

Related guides: SMD Screen Power Consumption and Stage LED Screen for Concerts.

Frequently asked questions

Q: Can any SMD screen be hung from a truss?

A: No. Only panels with a rated suspension system should be hung. Check the datasheet for the model, and ask the rigger to confirm the load before the screen goes up.

Q: Is ground stacking safer than hanging?

A: Neither is safe by default. Ground stacking has no overhead load, but it still needs a solid base and wind planning. Hanging needs a rated truss and a qualified rigger.

Q: How high can a stacked screen go?

A: The Absen FL Series supports stacking up to 5 metres in height, according to the product specification. The final height depends on the base, the wind and the site.

Q: Who should sign off a flown screen?

A: A qualified rigger should inspect and sign off the setup before the audience enters, and should check it again if the wind rises.


About this guide: Written by the Absen Pakistan team at Irfan Corporation, the authorised Absen distributor in Pakistan, with offices in Karachi and Islamabad. Product details come from Absen’s official specifications. Last updated: 13 November 2026.